Features
|
|
Specification
|
| | |
|
Internal calibration light source
|
|
Comes with its own internal light source for testing optical elements in double pass
|
| | |
|
External calibration light source
|
|
Comes with an external light source for testing optical elements in single pass
|
| | |
|
Optical elements (flat, converging or diverging) of practically any diameter can be tested
|
|
Using additional optical elements supplied by us, optical systems of practically any diameter and nature (diverging or converging) can be tested
|
| | |
|
Motorized beam-expander
|
|
Test elements of diameter of up to 58mm using our motorized beam-expander BE60. Optimum sampling is maintained over the whole diameter range. Beam expanders of up to 300mm output beam available on request
|
| | |
|
Optino wavefront sensor with cameras for the visible optimized for working at any wavelength between 350nm-1100nm
|
|
The system allows you to insert filters for performing the test at any wavelength
|
| | |
|
Optino wavefront sensor with IR camera works between 400nm-1800nm
|
|
High-quality Vidicon camera that can be operated from a laptop
|
| | |
|
Motorized collimator
|
|
Guarantees parallel light for every wavelength at which you wish to do the test
|
| | |
|
Modular design of instrument
|
|
Allows you flexibility in testing. Optical elements optimized for the particular wavelength can be used in the wavefront sensor and the beam-expanders
|
| | |
|
Modular design of software
|
|
Allows you flexibility in testing
|
| | |
|
Flexibility of changing the number of spots
|
|
Fewer spots can be used for a very fast analysis. For a detailed analysis up to
100 x100 spots can be used
|
| | |
|
Flexibility of changing the camera
|
|
The camera is mounted externally and can be changed if required. This allows different cameras to be mounted, which are optimized for different wavelength ranges or for different sampling
|
| | |
|
No thermal noise
|
|
Since the camera is mounted externally, no air turbulence is generated in the system, reducing noise
|
| | |
|
Portability: control from laptop
|
|
All the cameras offered with Optino wavefront sensor can be controlled from a laptop
|
| | |
|
Mounting of SH lenslet arrays
|
|
Different Shack-Hartmann lenslet arrays can be mounted on request
|
| | |
|
High dynamic range
|
|
Optino has a very wide dynamic range: e.g. hundreds of lambda of spherical aberration can be tested
|
| | |
|
Measurement of shape parameters (like asphericity)
|
|
Optino has a very wide dynamic range: e.g. hundreds of lambda of spherical aberration can be tested. This allows large conic coefficients to be measured
|
| | |
|
Real-time alignment: saves you time
|
|
Allows real time adjustment (alignment + focus) of reference and test CCD frames
|
| | |
|
Real-time collimation: saves you time
|
|
Allows real-time adjustment of the focus of the optical element
|
| | |
|
Check for air turbulence
|
|
Can be used to quantify air-turbulence in the manufacturing environment
|
| | |
|
Focal length measurement
|
|
Very precise measurement of focal length can be made at any wavelength, allowing chromatic effects to be studied
|
| | |
|
Wedge angle measurement
|
|
Wedge angles can be measured
|
| | |
|
MTF measurement
|
|
The MTF can be measured at any wavelength
|
| | |
|
Turn-key approach: full system for production
|
|
Your system: SpotOptics specializes in adapting our wavefront sensors for your special application and for the manufacturing environment
|
| | |
|
Full consultancy service provided
|
|
Our consultancy services are based on more than 15 years of experience in wavefront sensing and 20 years of experience in the field of optical metrology and image
|
| | |
|
Help
|
|
Very detailed Help and User Manual both for the use of the instrument and the theory (Shack-Hartmann principle, aberrations, Zernike and Seidel polynomials etc.
|
| | |